Leading US Manufacturer of
Heavy Duty Hinges & Door Operators

Unit of Measure

Mounting Information

N/A Right Hand Full Surface (closed position, opens 180° minimum)

Hinge Size

N/A 6 in. high x 7.58 in. wide

Base Material

N/A 1018 Cold Rolled Steel ASTM A108

Base Material (Optional)

N/A 304 Stainless Steel ASTM A276

Hinge Pin

N/A Aerospace quality, hardened alloy steel, Armoloy® coated

Finish: Steel/Stainless

N/A 600 USP Prime/Mill Finish

Mounting Holes: Steel/Stainless

N/A Drilled for (6) 5/8” diameter bolts

Bearing Type

N/A Needle rollers: thrust and radial (sealed from environment)

Door Weight (Max): Steel/Stainless

N/A 4000 lb3000 lb

Radial Capacity: Steel/Stainless

N/A 1700 lb1000 lb

Operating Torque (Frictional)

N/A 35 lbs-in (Theoretical value at full capacity. Actual value will depend on installation variables.)

Bolting: Steel

N/A Tensile strength= 120,000 psi minimum Tightening torque= 900 lbs-in minimum

Bolting: Stainless

N/A Tensile strength= 70,000 psi minimum Tightening torque=600 lbs-in minimum

Hinge Weight (approx.)

N/A 12 lb

Finish (Optional)

N/A 603 (US2G) – Zinc Clear Steel 626 (US26D) – Satin Chrome Steel 630 (US32D) – Buffed Satin Stainless Steel

Custom (Typical)

N/A Hinge leaf widths: single or double cut Special non-standard hole layouts (may require approval)

N/A

Series W hinges will function at the rated capacities providing the following specifications are met:


1. The hinge pin centerlines are installed collinear with each other in 2 vertical planes, and with no misalignment.


2. A minimum of 2 hinges (1 pair) are used per door.


3. Door weight or thrust load shall never exceed the thrust capacity of one hinge. In addition, the radial capacity shall not been exceeded.


4. When approaching the thrust and/or radial capacity in high frequency applications, it may be necessary to go up in hinge size in order to obtain the maximum safety factors for load-life on the roller bearings. Please consult the Engineering Department.


5. Compliance with bolting specification.


6. Minimum Thread engagement into reinforcing member shall be equal to bolt diameter.


7. For weld on applications, the minimum fillet weld size shall be as specified for the model number, and be full length on the top, bottom, and vertical edges of the mounting surface of each hinge leaf. There shall be no welding on the backside, adjacent to the hinge barrel. Assure the weld interpass temperature at the hinge barrel does not exceed 225 deg. F.


8. For high frequency applications, adequate load distribution between hinges is recommended to obtain the highest margin of safety with respect to load-life on the roller bearings. This can be accomplished using a torque wrench to equalize the load on the set screw of each hinge. The closer the torque value between each set screw, the closer the load distribution between hinges. In order to perform this task on very heavy doors, it may be necessary to temporarily lift some of the weight off the hinges.


8. Maximum (+) adjustment is 1/8" over nominal. During installation, we recommend pre-loading the hinges to remove any clearances that may develop from a tolerance "stack-up".